Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS101HTCB0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS101HTCB0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated furnace control for the ICP Tempstar Heil RGS101HTCB0AAA. The board is the brain of the furnace — it sequences the entire heating cycle, energizing the inducer, igniter, gas valve, and blower in the correct order while monitoring safety inputs like the pressure switch, limit switches, and flame sensor. It also runs the cooling and continuous-fan blower modes and stores diagnostic fault codes on its LED. When the control board fails, the furnace may be completely dead, stuck in lockout, short-cycle, or run the blower continuously. This complete kit is the direct OEM replacement and typically includes the mounting hardware and instructions needed for a clean swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Functions Ignition, blower, and safety sequencing
Diagnostics Onboard LED fault codes
Fit OEM Replacement Kit

Compatibility

Built for the ICP / Tempstar / Heil RGS101HTCB0AAA gas furnace and related ICP-family models using this integrated control. Confirm the board part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas. Verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace service panel to reach the control board in the blower compartment.
  3. Document — Photograph every wire harness and connector position on the old board before disconnecting.
  4. Remove — Unplug each connector, remove the mounting screws or standoffs, and lift out the failed board.
  5. Install — Mount the new board from the kit and reconnect each harness exactly as photographed; set any DIP switches or jumpers to match the original.
  6. Test — Restore gas and power, run a full heating and blower cycle, and confirm correct sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive on a heat call
  • Repeated lockouts or flashing diagnostic fault codes
  • Blower runs continuously or won't start
  • Burnt smell, scorch marks, or visible damage on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101HTCB0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101HTCB0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101HTCB0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online