Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS101HFCA0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS101HFCA0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control for the ICP / Tempstar / Heil RGS101HFCA0AAA. The board is the brain of the furnace: it sequences the inducer, igniter, gas valve, and blower while monitoring the pressure switch, flame sensor, and limit safeties. Supplied as a complete kit, it includes the board and the mounting and connection hardware needed for a direct swap. Control boards fail from heat stress, power surges, cracked solder joints, and burned relays. Typical symptoms include a furnace that is completely dead, an inducer that runs but never advances to ignition, a blower that will not start or will not shut off, or repeated lockouts with no obvious sensor fault. Replacing the board restores correct timing and the full chain of safety supervision.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, blower, inducer & safety control
Application Gas Furnace
Fits Model RGS101HFCA0AAA

Compatibility

Direct OEM fit for the ICP, Tempstar, Heil, and Comfortmaker RGS101HFCA0AAA furnace. Confirm the board's part number and connector layout against your existing control before installing. Note any DIP switch or timing settings on the old board and replicate them on the new one.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every wire and connector and note any DIP switch positions.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift the old board out.
  5. Install — Mount the new board, transfer DIP settings, and reconnect every harness to match your photos.
  6. Test — Restore gas and power and verify a full ignition sequence and proper blower operation.

Signs You Need a Replacement

  • Furnace is completely unresponsive with power confirmed.
  • Inducer runs but ignition never begins.
  • Blower will not start or will not shut off.
  • Repeated lockouts or error codes with healthy sensors.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101HFCA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101HFCA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101HFCA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online