Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS101HECA0AAA | Ships Today
ICP

ICP Furnace Control Board Kit for RGS101HECA0AAA | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM control board kit (part 1183618) for the ICP / Tempstar / Heil model RGS101HECA0AAA gas furnace. The integrated furnace control board is the brain of the system: it manages the ignition sequence, monitors safety circuits such as limit and pressure switches, controls the inducer and blower motors, and times each stage of the heat and cool cycle. A failed board produces a wide range of symptoms - no ignition, no blower, error-code lockouts, or a furnace that ignites then shuts down. Because the board governs every safety interlock, a faulty unit should be replaced promptly with the correct factory kit, which includes the board and mounting hardware for a complete repair.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, blower, inducer, and safety control
Includes Control board and mounting hardware
Fits Model RGS101HECA0AAA

Compatibility

Engineered as a direct replacement for the integrated control board on ICP-built RGS101HECA0AAA furnaces and matching Tempstar, Heil, and Comfortmaker models. Confirm the board part number and connector layout against your existing board before ordering.

Installation Guide

  1. Safety First - Disconnect power at the breaker and verify zero voltage with a multimeter before touching the board.
  2. Access - Remove the furnace control compartment panel.
  3. Document - Photograph every connector, plug, and wire position on the old board.
  4. Remove - Unplug all harnesses, remove the mounting screws, and lift out the failed board.
  5. Install - Mount the new board with the supplied hardware and transfer each connector to the matching terminal per your photo.
  6. Test - Restore power, run a full heat cycle, and confirm correct ignition, blower, and shutdown sequencing with no error codes.

Signs You Need a Replacement

  • No ignition, no blower, or no response on a call for heat
  • Furnace lights then shuts down or short-cycles
  • Diagnostic LED flashing fault or lockout codes
  • Visible scorching, corrosion, or damaged relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101HECA0AAA | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101HECA0AAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101HECA0AAA | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online