Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS091LSCB0AAA — Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS091LSCB0AAA — Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated ignition control that runs the entire sequence of operation on the ICP RGS091LSCB0AAA gas furnace. It manages the inducer, hot surface igniter, gas valve timing, flame sensing, and blower on/off delays, while monitoring the pressure switch and limit safeties. When the board fails, the furnace may not respond to the thermostat, lock out after ignition, run the blower continuously, or throw erratic fault codes on its diagnostic LED. Because the board interprets every safety input, a failing board is a common cause of intermittent no-heat calls that seem to come and go.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace ignition control board kit
Brand ICP (Tempstar / Heil)
Controls Igniter, inducer, gas valve, flame sense, blower timing
Diagnostics On-board LED fault codes
Fitment RGS091LSCB0AAA

Compatibility

Engineered for the ICP / Tempstar / Heil RGS091LSCB0AAA gas furnace and related RGS-series units that use this control board. Compare the board layout, connector positions, and part number to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment door.
  3. Document — Photograph every wire harness and plug on the existing board before disconnecting.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift the old board out.
  5. Install — Mount the new board on the same standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm proper igniter, gas valve, and blower sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace unresponsive to the thermostat with no LED activity
  • Repeated lockouts or erratic, changing fault codes
  • Blower runs constantly or never starts
  • Visible burn marks, scorching, or a failed relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091LSCB0AAA — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091LSCB0AAA — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091LSCB0AAA — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online