Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS091LDCA0AAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS091LDCA0AAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The ICP 1183618 is an OEM control board kit for the RGS091LDCA0AAA gas furnace — the integrated furnace control (IFC) that orchestrates the entire heating and blower sequence. It manages the call for heat, energizes the inducer, monitors the pressure switch, fires the hot surface igniter, opens the gas valve, reads the flame sensor for flame proving, and times the blower on/off delays. It also runs the safety logic that locks the furnace out on failed ignition, flame loss, or a stuck pressure switch, and flashes diagnostic fault codes via its onboard LED. A failed board produces erratic, intermittent, or dead-furnace symptoms that mimic many other parts. Supplied as a kit with the required mounting hardware and harness adapters for a clean OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, Blower & Safety Control
Diagnostics Onboard LED Fault Codes
Fits Model RGS091LDCA0AAA
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for ICP, Tempstar, Heil, and Comfortmaker RGS091LDCA0AAA series gas furnaces using this integrated furnace control. Match the board's part number and connector layout to your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter; shut off the gas supply.
  2. Access — Remove the blower or control compartment service panel.
  3. Document — Photograph every connector and the board's orientation before unplugging anything — labeled plugs make reassembly foolproof.
  4. Remove — Unplug each harness connector, remove the board mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reseat every connector fully per your photo, confirming each plug clicks home.
  6. Test — Restore gas and power, then run a full heat cycle and confirm correct ignition, flame proving, and blower timing with no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead with no LED activity on the board
  • Intermittent no-heat calls that don't trace to igniter, valve, or sensor
  • Blower runs constantly or fails to start after ignition
  • Visible scorching, burnt traces, or a tripped onboard fuse on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091LDCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091LDCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091LDCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online