Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS091HSCA0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS091HSCA0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board kit (part number 1183618) is the integrated brain of your ICP Tempstar/Heil RGS091HSCA0AAA gas furnace. It manages the ignition sequence, blower and inducer timing, safety lockouts, and communication between the thermostat, gas valve, and limit switches. When the board fails you may see no ignition, the furnace short-cycling, the blower running continuously, or a blinking diagnostic LED with no heat call response. This 24V control board ships as a complete kit so the failed assembly can be swapped without hunting for separate components.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fitment OEM Replacement
Model RGS091HSCA0AAA

Compatibility

Engineered as a direct OEM replacement for the ICP Tempstar Heil RGS091HSCA0AAA gas furnace. ICP-family equipment (Tempstar, Heil, Comfortmaker) shares many control platforms — always verify the printed part number 1183618 against the board currently installed.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector location on the existing board before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage harnesses, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new 1183618 board, then reconnect every harness exactly per your photo.
  6. Test — Restore power, initiate a heat call, and confirm the full ignition-to-blower sequence and a steady diagnostic LED.

Signs You Need a Replacement

  • No response to a thermostat heat call despite power present
  • Blower or inducer runs continuously or won't start
  • Furnace short-cycles or locks out repeatedly
  • Diagnostic LED flashes a fault code or stays dark

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HSCA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HSCA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HSCA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online