Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS091HRCA0AAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS091HRCA0AAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board kit (part 1183618) is the integrated ignition control module for the ICP / Tempstar / Heil RGS091HRCA0AAA gas furnace. The board is the brain of the furnace — it sequences the inducer motor, hot surface igniter, gas valve, and blower while continuously monitoring the pressure switch, limit switches, and flame sensor for safe operation. When the board fails you may see no response to a thermostat call, the inducer running but no ignition, the blower failing to start, error codes flashing on the diagnostic LED, or completely dead operation. A failed board often results from voltage surges, moisture, cracked solder joints, or burned relay contacts. This kit ships as a direct OEM replacement so the firmware and timing match the original.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement
Application Gas Furnace Ignition & Blower Control
Diagnostics On-board status LED

Compatibility

Designed for the ICP, Tempstar, and Heil RGS091HRCA0AAA furnace. Part number 1183618 ensures correct connector layout, relay ratings, and ignition timing for this model.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting.
  4. Remove — Unplug all harness connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, transfer each connector to its matching terminal per your photo, and set any jumpers/DIP switches to match.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower delay, and a steady diagnostic LED.

Signs You Need a Replacement

  • No response when the thermostat calls for heat
  • Inducer runs but igniter or gas valve never energizes
  • Blower will not start or runs continuously
  • Fault codes flashing or a dead diagnostic LED

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HRCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HRCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HRCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online