Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS091HECA0AAA gas furnace. The board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety limits and the flame sensor, and times each stage of the heating cycle. When the board fails, the furnace may not respond to the thermostat, fail to ignite, short-cycle, or run the blower continuously. Supplied as a complete kit with the hardware and instructions needed for a direct, factory-spec replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, blower/inducer sequencing, safety monitoring
Includes Control board and mounting kit
Fit OEM, direct replacement
Application Gas furnace

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS091HECA0AAA gas furnace and related RGS091 models that specify control board kit 1183618. Because control board part numbers are revision-specific, confirm 1183618 against your furnace's rating plate or parts diagram before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything; note plug locations.
  4. Remove — Disconnect all harness plugs, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board from the kit and reconnect every plug to its matching location per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat
  • No ignition sequence or inducer/blower fails to start
  • Blower runs continuously or short-cycles
  • Error/diagnostic LED codes pointing to control failure

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HECA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HECA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HECA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online