This genuine OEM control board kit (PN 1183618) for the ICP/Heil/Tempstar RGS091HDCB0AAA gas furnace is the integrated furnace control (IFC) that sequences the entire heat cycle - inducer start, igniter warm-up, gas valve, flame proving, and blower timing - while monitoring safety limits and pressure switches. The board's relays, flame-sense circuit, and microprocessor are vulnerable to power surges, moisture, and heat, and a failed board can leave the furnace dead, short-cycling, or stuck in a fault lockout (often shown by the diagnostic LED). This kit replaces the board with a factory-matched control to restore proper, safe operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board
Brand ICP / Heil / Tempstar
Functions Ignition, Blower, Safety Sequencing
Application Gas Furnace Control

Compatibility

Designed for the ICP/Heil/Tempstar RGS091HDCB0AAA gas furnace and related models using the same integrated furnace control. Match the board part number and connector layout before ordering.

Installation Guide

  1. Safety First - Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access - Remove the control/blower compartment service panel.
  3. Document - Photograph every plug and wire location on the old board before disconnecting.
  4. Remove - Unplug each connector, release the board standoffs/screws, and lift out the old control.
  5. Install - Mount the new board, transfer each connector to the matching terminal exactly per your photo.
  6. Test - Restore power, run a full heat cycle, and confirm proper ignition, flame proving, and blower operation with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to a heat call
  • Repeated short-cycling or safety lockouts
  • Diagnostic LED flashing a hard fault code
  • Burned, corroded, or scorched spots on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HDCB0AAA - OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HDCB0AAA - OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HDCB0AAA - OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online