Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) — the brain of the ICP RGS090SRCA0AAA gas furnace. It manages the entire heating sequence: it powers the inducer, proves the pressure switch, energizes the hot surface igniter, opens the gas valve, monitors the flame sensor, and controls the blower motor timing. The board also runs self-diagnostics and flashes fault codes via its onboard LED. Boards fail from voltage surges, overheating, corroded relays, or burnt traces — symptoms include a completely dead furnace, no inducer start, no igniter sequence, or erratic blower behavior.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Function Ignition, blower & safety sequencing
Diagnostics Onboard LED fault codes
Includes Control board mounting kit

Compatibility

Direct OEM replacement for the ICP RGS090SRCA0AAA furnace and shared across many Tempstar, Heil, and Comfortmaker furnaces using this integrated control. Confirm the board part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment door to expose the board.
  3. Document — Photograph every wire harness and terminal before disconnecting — this is the most critical step.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect each harness exactly per your photo.
  6. Test — Restore gas and power, call for heat, and watch the full sequence complete with a steady LED status.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity
  • Inducer or igniter sequence never starts on a heat call
  • Blower runs constantly or won't run at all
  • Visible burnt relays, scorched traces, or a hard-fault LED code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SRCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SRCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SRCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.