This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS090SRBB0AAA gas furnace. The board is the brain of the furnace: it manages the ignition sequence, sequences the inducer and blower motors, monitors the flame sensor and pressure switch safeties, and flashes diagnostic fault codes. Supplied as a complete kit, it includes the components needed for a clean retrofit. When a control board fails the furnace may be completely dead, stuck in continuous blower operation, locked out on a flashing error code, or behaving erratically across heat cycles. Power surges, blown fuses, and burnt relays are common culprits. Because the board ties every safety and sequence together, replacing a failed board restores reliable, code-compliant operation across the whole furnace.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition control, blower/inducer sequencing, safety monitoring, diagnostics
Fitment OEM

Compatibility

Built for the ICP Tempstar Heil RGS090SRBB0AAA gas furnace and related ICP-family models calling for control board kit 1183618. Match the board layout, connector count, and harness keying to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every connector and wire location on the existing board before unplugging anything.
  4. Remove — Unplug each harness, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and reconnect every harness to the matching terminal per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm normal ignition, blower operation, and a steady (no-fault) status LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive on a call for heat
  • Flashing diagnostic fault code or repeated hard lockout
  • Blower runs continuously or fails to start
  • Visible burnt relays, scorched traces, or a blown onboard fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SRBB0AAA | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SRBB0AAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SRBB0AAA | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online