Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS090SRBA0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS090SRBA0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the brain of your ICP Tempstar/Heil RGS090SRBA0AAA gas furnace. The integrated furnace control manages the entire heating sequence: it reads the thermostat call, runs the inducer and pressure switch proving, energizes the hot surface igniter, opens the gas valve, monitors flame via the flame sensor, and times the blower on/off delays. It also runs continuous safety supervision of the limit and rollout switches. When the board fails, the furnace can go completely dead, fail to start the ignition sequence, run the blower continuously, or throw erratic diagnostic flash codes. Because the board controls every safety interlock, a failed or intermittently failing board should always be replaced with the correct OEM part rather than bypassed.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Line Voltage 120V
Control Voltage 24V

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS090SRBA0AAA gas furnace and compatible ICP-family models (Tempstar, Heil, Comfortmaker, Arcoaire). The kit includes mounting hardware and connectors to match the original board footprint.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every connector and wire location on the old board before unplugging anything.
  4. Remove — Unplug all harnesses, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board and transfer each connector to the identical terminal per your photos.
  6. Test — Restore power, call for heat, and verify the full ignition-to-blower sequence runs and the diagnostic LED shows a normal code.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Ignition sequence never starts or stalls
  • Blower runs constantly or won't shut off
  • Erratic or hard-fault diagnostic flash codes

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SRBA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SRBA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SRBA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.