Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS090SRAB0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS090SRAB0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP / Tempstar / Heil RGS090SRAB0AAA gas furnace. The board is the brain of the furnace: it sequences the inducer, igniter, gas valve, and blower, monitors the flame-sense and pressure-switch safeties, and manages timing and lockouts. Supplied as a complete kit, it includes the mounting hardware needed for a clean swap. A failed board typically presents as a dead furnace, an inducer or blower that won't run, or a flashing diagnostic LED that won't clear.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Application Gas Furnace Sequencing & Safety

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS090SRAB0AAA. Control boards are model-specific — match the OEM part number 1183618 and confirm the connector layout against your original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every connector and the existing diagnostic-LED reference before unplugging anything.
  4. Remove — Unplug each harness, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect every harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct inducer, ignition, and blower sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace completely dead with no response to a call
  • Inducer or blower motor won't energize
  • Persistent or erratic diagnostic LED fault codes
  • Burn marks, scorched relays, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SRAB0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SRAB0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SRAB0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online