Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS090SRAA0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS090SRAA0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM furnace control board kit (part number 1183618) is the integrated ignition control for the ICP / Tempstar / Heil RGS090SRAA0AAA gas furnace. The board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower, monitors the flame sensor and limit/pressure switches, and runs diagnostic LED fault codes. A failed control board produces erratic behavior: no ignition, blower that won't stop, intermittent lockouts, or a completely dead furnace. This OEM kit restores correct, safe control with all factory firmware and timing.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS090SRAA0AAA
Features Ignition control, blower/inducer timing, diagnostic LED codes
Fit OEM direct replacement

Compatibility

Direct-fit replacement for the ICP RGS090SRAA0AAA and shared Tempstar/Heil/Comfortmaker furnaces using this integrated control board. Match the part number and connector layout to your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect furnace power and verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every connector and wire position on the old board before disconnecting.
  4. Remove — Unplug all harness connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer any jumpers/settings, and reconnect each harness per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm normal ignition, blower operation, and no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead with no diagnostic LED activity
  • No ignition sequence despite a valid heat call
  • Blower runs continuously or cycles erratically
  • Repeated unexplained lockouts or fault codes pointing to the control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SRAA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SRAA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SRAA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online