This OEM control board kit (part 1183618) is the integrated furnace control (IFC) — the "brain" of the ICP / Tempstar / Heil RGS090SEAB0AAA gas furnace. It manages the entire heating sequence: it reads the thermostat call, runs the inducer and pressure-switch proof, energizes the hot surface igniter, opens the gas valve, monitors the flame sensor, and times the blower on and off. It also coordinates cooling-mode blower operation and stores diagnostic fault codes on its LED. When the board fails, the furnace may be completely dead, stuck on continuous fan, or unable to complete ignition despite good supporting components.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board (kit)
Brand ICP / Tempstar / Heil
Function Ignition control, blower timing, diagnostics
Fits Model RGS090SEAB0AAA
Fit OEM direct replacement

Compatibility

Designed for the RGS090SEAB0AAA furnace and used across many ICP-family gas furnaces marketed under Tempstar, Heil, Comfortmaker, and Arcoaire. Confirm the OEM number on your existing board, as ICP used several board revisions across production runs.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower/control-compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all connectors, release the mounting standoffs/screws, and lift the old board out.
  5. Install — Mount the new board, then reconnect each harness exactly as photographed, seating every connector fully.
  6. Test — Restore power, run a full heat cycle, and confirm ignition, flame proof, and proper blower timing with no fault-code flashes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity on the board.
  • Blower runs continuously or won't start despite a valid thermostat call.
  • Visible burnt traces, scorched relays, or a cracked board.
  • Erratic operation or fault codes that persist after replacing igniter, sensor, and switches.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SEAB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SEAB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SEAB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online