Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS090SEAA0AAA – Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS090SEAA0AAA – Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the brain of your ICP RGS090SEAA0AAA gas furnace. It manages the entire heating sequence — inducer startup, pressure-switch proving, igniter warm-up, gas valve timing, flame sensing, and blower control — and includes built-in safety lockouts. A failed board is a frequent cause of no-heat calls. Common symptoms include a completely dead furnace, an ignition sequence that never starts, the blower running continuously or not at all, error/diagnostic LED fault codes, or visible burn marks, corrosion, or failed relays on the board itself.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Ignition Control Board Kit
Brand ICP
Operating Voltage 120V Line / 24V Control
Function Ignition sequencing, blower & safety control

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS090SEAA0AAA gas furnace and compatible ICP-family units that use this control board kit. The kit format includes the necessary mounting and connection components for a clean swap.

Installation Guide

  1. Safety First – Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access – Remove the control/blower compartment service panel.
  3. Document – Photograph every plug and terminal on the existing board before disconnecting.
  4. Remove – Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install – Mount the new board and transfer each connector to the matching terminal per your photo.
  6. Test – Restore power and confirm a complete, fault-free ignition and heating cycle.

Signs You Need a Replacement

  • Furnace is completely unresponsive on a heat call
  • Ignition sequence never begins or stalls mid-cycle
  • Blower runs constantly or refuses to start
  • Diagnostic LED shows a control or hardware fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SEAA0AAA – Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SEAA0AAA – Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SEAA0AAA – Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online