This OEM integrated furnace control board (circuit board P/N 1178358 with ignition control module 1177661) is the central brain of your ICP Tempstar Heil WPG3304060RKC1 packaged gas/electric unit. It manages the ignition sequence, sequences the inducer and blower motors, monitors flame via the sensor, and runs onboard safety and diagnostic functions. When this board fails you may see no heat, a unit that locks out on ignition, blower or inducer motors that won't energize, or a flashing diagnostic LED. Replacing a failed board with the correct OEM part restores the full factory ignition and safety logic.

Specifications

Spec Value
Part Number 1178358 (Circuit Board) / 1177661 (Ignition Control Module)
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24V
Fits Model WPG3304060RKC1
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP Tempstar Heil WPG3304060RKC1 packaged gas/electric unit and closely related WPG-series models that share the same control platform. Always confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every wire and connector position on the existing board before disconnecting anything.
  4. Remove — Unplug the molex harnesses and spade terminals, remove the board mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect every harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle; confirm inducer, ignition, flame proving, and blower all sequence correctly and the diagnostic LED shows normal.

Signs You Need a Replacement

  • No heat with a unit that locks out or never attempts ignition
  • Inducer or blower motor fails to energize on a heat call
  • Continuous fault/error code flashing on the board's diagnostic LED
  • Visible burn marks, corrosion, or scorched traces on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPG3304060RKC1 — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPG3304060RKC1 — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPG3304060RKC1 — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online