This genuine ICP furnace control board (OEM circuit board 1178358 with ignition control module 1177661) is the brain of your ICP / Tempstar / Heil WPG3304060LKC1 package gas-electric unit. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, firing the hot-surface igniter, opening the gas valve, monitoring the flame sensor, and timing the blower on and off. It also manages safety lockouts and flashes diagnostic fault codes through its onboard LED. When the board fails you may see no ignition at all, an inducer that runs but never lights the burners, intermittent no-heat calls, a blower that won't shut off, or a board with no LED activity. Burned relay contacts, scorched traces near the gas-valve terminals, and cracked solder joints are all clear signs the board has reached end of life.

Specifications

Spec Value
Part Numbers 1178358 (circuit board), 1177661 (ignition control module)
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Function Ignition sequencing, blower timing, safety lockout, diagnostics
Fitment OEM direct replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WPG3304060LKC1 package gas-electric unit and related WPG-series models using the 1178358 board with the 1177661 ignition control. Match the part numbers and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter before opening the control area.
  2. Access — Remove the blower/control service panel to expose the control board and its harness.
  3. Document — Photograph every plug, wire color, and terminal position before disconnecting anything.
  4. Remove — Unplug the wiring harnesses, release the mounting standoffs or screws, and lift out the failed board.
  5. Install — Seat the new board on its standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, start a heat call, and confirm a full ignition sequence with no fault codes and correct blower timing.

Signs You Need a Replacement

  • No ignition and no diagnostic LED activity on the board
  • Inducer runs but igniter or gas valve never energizes
  • Blower runs continuously or fails to start on a heat call
  • Visible burned relays, scorched traces, or cracked solder joints

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPG3304060LKC1 — Integrated Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPG3304060LKC1 — Integrated Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPG3304060LKC1 — Integrated Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online