Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WPG3244040LKC1 — Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board for WPG3244040LKC1 — Integrated Ignition Control | Ships Today

SKU: 1178358 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board (part #1178358) and its companion ignition control module (#1177661) are the electronic brain of the ICP/Tempstar/Heil WPG3244040LKC1 packaged gas unit. The board manages the ignition sequence, monitors flame, sequences the inducer and blower, and runs continuous safety diagnostics. When it fails, the furnace may lock out, short-cycle, fail to ignite, or flash diagnostic fault codes on its LED. A failed control board is one of the most common causes of complete no-heat conditions on this platform. This is a genuine OEM-spec replacement that matches the original timing, pinout, and 24V control logic.

Specifications

Spec Value
Part Number 1178358 (Circuit Board), 1177661 (Ignition Control Module)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Ignition control, flame sensing, blower & inducer sequencing
Fit OEM

Compatibility

Engineered as a direct replacement for the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire model WPG3244040LKC1 packaged gas/electric unit. Always verify the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph all wire connections and harness routing before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, reconnect every harness exactly per your photo, confirming connectors are fully seated.
  6. Test — Restore power, initiate a heat call, and watch for a clean ignition sequence with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or locks out after several trial attempts
  • Blower or inducer motor fails to start or runs continuously
  • Diagnostic LED flashing a hard-fault or control-failure code
  • Intermittent no-heat that resets after a power cycle

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WPG3244040LKC1 — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WPG3244040LKC1 — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WPG3244040LKC1 — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online