Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WFHR120D060A1 — OEM CEPL130438-01 | Ships Today
ICP

ICP Furnace Control Board for WFHR120D060A1 — OEM CEPL130438-01 | Ships Today

SKU: 1176943 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM integrated furnace control board (part number 1176943, CEPL130438-01) is the brain of the ICP / Tempstar / Heil WFHR120D060A1 furnace. It manages the entire heat sequence — inducer operation, hot surface igniter timing, gas valve actuation, blower on/off delays, and all safety lockouts from the pressure switch, limit, and flame sensor. When the board fails, symptoms range from a completely dead furnace to erratic blower behavior, failure to ignite, or repeated safety lockouts. The on-board diagnostic LED flash codes help confirm a board fault versus an external component before replacement.

Specifications

Spec Value
Part Number 1176943
OEM Board Number CEPL130438-01
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Functions Ignition, blower, inducer, safety control
Fitment OEM

Compatibility

Built for the ICP Tempstar Heil WFHR120D060A1 and other ICP-family furnaces specifying control board CEPL130438-01 / part 1176943. Match the full board part number to your original before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every wire harness and terminal connection on the old board before disconnecting.
  4. Remove — Unplug all harnesses, release the board mounting standoffs/screws, and lift the old board out.
  5. Install — Mount the new board, transfer each connector to its identical terminal per your photo, and confirm any jumper/dip settings match.
  6. Test — Restore gas and power, run a full heat cycle, and verify the diagnostic LED shows a normal status code.

Signs You Need a Replacement

  • Furnace completely dead with 24V control power present
  • No response to a heat call — no inducer, igniter, or blower
  • Diagnostic LED off, solid, or showing a hardware/internal fault code
  • Burnt spots, scorched relays, or corroded traces on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFHR120D060A1 — OEM CEPL130438-01 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFHR120D060A1 — OEM CEPL130438-01 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFHR120D060A1 — OEM CEPL130438-01 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online