This genuine OEM integrated furnace control board (part #1176943, board #CEPL130438-01) is the brain of your ICP Tempstar/Heil WFHR100C060A1 furnace. It manages the entire heating sequence — ignition timing, gas valve operation, inducer and blower relays, safety limit monitoring, and flame sensing. When the board fails the furnace can become completely unresponsive or behave erratically. Common symptoms include no response on a call for heat, the inducer or blower failing to energize, intermittent shutdowns, error/diagnostic LED fault codes, or visible burn marks, corrosion, or scorched relays on the board itself.

Specifications

Spec Value
Part Number 1176943
Board Number CEPL130438-01
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil)
Function Ignition, Blower, Inducer & Safety Control
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil WFHR100C060A1 furnace and related ICP-family units that use control board CEPL130438-01. Always match the exact board number before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment service panel.
  3. Document — Photograph every wiring harness and connector position on the board before disconnecting.
  4. Remove — Unplug each connector, remove the board mounting screws/standoffs, and lift the old board out.
  5. Install — Mount the new board and reconnect each harness to its matching terminal exactly per your photo.
  6. Test — Restore power, initiate a call for heat, and confirm a complete ignition and blower cycle with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive on a call for heat
  • Inducer or blower motor fails to energize
  • Diagnostic LED displays a control fault code
  • Intermittent or random furnace shutdowns
  • Visible burn marks, corrosion, or scorched relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFHR100C060A1 — OEM CEPL130438-01 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFHR100C060A1 — OEM CEPL130438-01 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFHR100C060A1 — OEM CEPL130438-01 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online