Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WFAR120D066B1 — OEM Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board for WFAR120D066B1 — OEM Integrated Ignition Control | Ships Today

SKU: 1184783 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board, part number 1184783, is the factory-specified circuit board for the ICP Tempstar Heil WFAR120D066B1 gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, monitors safety limits and pressure switches, energizes the igniter and gas valve, and controls blower and inducer timing. When the board fails, the furnace may fail to start, short-cycle, lock out, run the blower continuously, or throw error codes on its diagnostic LED. Replacing a failed control board restores safe, sequenced operation and resolves the intermittent electrical faults that mimic many other component failures.

Specifications

Spec Value
Part Number 1184783
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Function Ignition, Safety & Blower Control
Fits Model WFAR120D066B1
Application Gas Furnace
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP Tempstar Heil WFAR120D066B1 furnace and interchangeable across ICP-family brands (Comfortmaker, Heil, Tempstar, Arcoaire) that share this control platform. Confirm the OEM part number printed on your existing board before ordering, as ICP uses several board revisions.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment service panel.
  3. Document — Photograph every wire harness and terminal on the board before disconnecting anything.
  4. Remove — Unplug each connector, remove the board mounting screws, and lift out the old control board.
  5. Install — Mount the new board, transfer any jumpers or settings, and reconnect every harness exactly per your photo.
  6. Test — Restore power and run a full heat cycle, watching the diagnostic LED to confirm normal sequencing and no fault codes.

Signs You Need a Replacement

  • Furnace will not start or randomly fails to ignite
  • Blower or inducer runs continuously or not at all
  • Repeated lockouts or flashing diagnostic error codes
  • Burned, corroded, or scorched traces and relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFAR120D066B1 — OEM Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFAR120D066B1 — OEM Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFAR120D066B1 — OEM Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online