Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WFAR080C060A1 — OEM 1184783 Integrated Furnace Control | Ships Today
ICP

ICP Furnace Control Board for WFAR080C060A1 — OEM 1184783 Integrated Furnace Control | Ships Today

SKU: 1184783 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board (part number 1184783) is the central electronic brain of your ICP / Tempstar / Heil WFAR080C060A1 gas furnace. It sequences ignition, controls blower on/off timing, drives the gas valve, monitors flame sensing, and enforces safety lockouts. When this board fails, the furnace may not ignite, short-cycle, blow cold air, run the blower nonstop, or report a fault through its diagnostic LED. A failed control board is one of the most common no-heat causes on this furnace platform. A genuine OEM replacement restores complete control of the heating cycle while keeping your factory safety interlocks intact.

Specifications

Spec Value
Part Number 1184783
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Function Ignition, blower & safety control
Diagnostics Onboard fault-code LED
Fit OEM direct replacement

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil WFAR080C060A1 gas furnace. This board is shared across many ICP-family furnaces using the 1184783 control; always confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug the wiring harnesses and molex connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new 1184783 board, then reconnect each harness exactly per your photo.
  6. Test — Restore power, start a heat call, and confirm a clean ignition sequence and correct blower timing.

Signs You Need a Replacement

  • Furnace will not ignite or has no response on a heat call
  • Blower runs continuously or never starts
  • Short-cycling or repeated safety lockouts
  • Diagnostic LED flashing a hard-fault code or completely dark

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFAR080C060A1 — OEM 1184783 Integrated Furnace Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFAR080C060A1 — OEM 1184783 Integrated Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFAR080C060A1 — OEM 1184783 Integrated Furnace Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.