Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WFAR060A042A1 — Integrated Ignition | Ships Today
ICP

ICP Furnace Control Board for WFAR060A042A1 — Integrated Ignition | Ships Today

SKU: 1184783 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board (part #1184783) is the brain of your ICP Tempstar Heil WFAR060A042A1 gas furnace. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, firing the hot surface igniter, opening the gas valve, monitoring flame through the sensor, and timing blower on/off delays. It also enforces the furnace's safety limits and stores diagnostic fault codes via its on-board LED. When the control board fails, symptoms range from a completely dead furnace to erratic operation: no ignition sequence, the blower running constantly, intermittent lockouts, or a flashing error code with no obvious cause. Boards fail from power surges, voltage spikes, corroded relays, and heat-stressed solder joints.

Specifications

Spec Value
Part Number 1184783
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil)
Function Ignition, blower & safety control
Diagnostics On-board LED fault codes
Fitment OEM Direct Replacement

Compatibility

Factory replacement for the ICP Tempstar Heil WFAR060A042A1 gas furnace and compatible ICP-family furnaces using the same integrated control board. Confirm the board's part number and connector layout match your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power and gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire harness and connector on the board before disconnecting.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer each harness to the matching terminal per your photo, and set any DIP/blower-timing switches to match the original.
  6. Test — Restore power and gas, call for heat, and watch the full ignition sequence and blower timing complete with no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead with line voltage present
  • No ignition sequence starts on a heat call
  • Blower runs continuously or won't run at all
  • Repeated lockouts or a flashing diagnostic fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFAR060A042A1 — Integrated Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFAR060A042A1 — Integrated Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFAR060A042A1 — Integrated Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera