Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for WFAR040A030A1 — Integrated Control | Ships Today
ICP

ICP Furnace Control Board for WFAR040A030A1 — Integrated Control | Ships Today

SKU: 1184783 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM integrated furnace control board (part number 1184783) for the ICP/Tempstar/Heil WFAR040A030A1 furnace. The control board is the brain of the furnace — it sequences the draft inducer, hot surface igniter, gas valve, and blower while monitoring the pressure switch, limit switches, and flame sensor for safe operation. A failed control board produces a wide range of symptoms: no response to the thermostat, an inducer or blower that will not start, an igniter that never energizes, or a board that locks out and flashes a diagnostic fault code. Boards commonly fail from voltage surges, cracked solder joints, blown onboard fuses, or burnt relay contacts. Replacing with the correct OEM board restores the full ignition and safety sequence.

Specifications

Spec Value
Part Number 1184783
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Application Furnace Ignition & Blower Control
Fitment OEM Replacement

Compatibility

Direct factory replacement for the ICP/Tempstar/Heil WFAR040A030A1 furnace and the Comfortmaker, Arcoaire, and KeepRite versions of this model platform. Match the board's connector layout and part number to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every wire harness and connector position before disconnecting anything.
  4. Remove — Unplug all harnesses, note the blower speed tap locations, and unscrew the old board from its standoffs.
  5. Install — Mount the new board, transfer each harness to the matching connector per your photo, and confirm the blower speed taps are correct.
  6. Test — Restore power and run a full heat cycle, watching for a clean ignition sequence and no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Inducer, igniter, or blower fails to energize in sequence
  • Repeated lockouts or a flashing diagnostic fault code
  • Burnt relay, scorched traces, or a blown onboard fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFAR040A030A1 — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFAR040A030A1 — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFAR040A030A1 — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online