This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP/Tempstar/Heil RGX036KECA0AAA gas furnace. It sequences the entire heating cycle — inducer start, pressure switch proving, igniter warm-up, gas valve timing, blower on/off delays, and safety lockouts — and reads the flame sensor to confirm ignition. When the board fails, the furnace may be completely dead, stuck on continuous blower, flashing diagnostic fault codes, or short-cycling. Replacing it with the correct OEM kit restores proper timing and safety control. The kit ships with the board and required mounting hardware where applicable.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGX036KECA0AAA
Application Gas Furnace Control
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGX036KECA0AAA furnace and other ICP-family models that originally used board 1183618. Confirm the printed board number and connector layout match your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every wire and terminal on the existing board before disconnecting anything.
  4. Remove — Unplug the harnesses and low-voltage leads, then remove the board mounting screws.
  5. Install — Mount the new board and reconnect each connector exactly per your photo; set any dip switches/jumpers to match the original.
  6. Test — Restore power and run a full heat cycle; verify normal sequencing and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no diagnostic LED.
  • Blower runs continuously or fails to start.
  • Persistent fault-code flashes pointing to the control.
  • Erratic short-cycling not explained by sensors or switches.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGX036KECA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGX036KECA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGX036KECA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.