Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS336LEFA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS336LEFA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM furnace control board kit (part number 1183618) is the brain of the ICP/Tempstar/Heil RGS336LEFA0AAAA gas furnace. The integrated furnace control (IFC) manages the ignition sequence, blower timing, inducer motor operation, gas valve activation, and built-in safety interlocks. When this board fails, the furnace may fail to ignite, short-cycle, run the blower continuously, or lock out entirely. A flashing diagnostic LED that no longer responds, no 24V output to the gas valve, or a furnace that is completely unresponsive are all classic signs of a failed control board. Installing the correct OEM kit restores reliable, code-compliant operation.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS336LEFA0AAAA
Diagnostics On-board LED fault codes

Compatibility

Designed as the factory replacement for the ICP/Tempstar/Heil RGS336LEFA0AAAA gas furnace and shared family variants that originally used kit 1183618. Always confirm your existing board's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug the low-voltage and line-voltage harnesses, release the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new 1183618 board, then reconnect each harness exactly per your photos.
  6. Test — Restore power and confirm a full ignition cycle, blower operation, and a normal diagnostic LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity
  • No 24V signal to the gas valve or inducer during a call for heat
  • Repeated lockouts or erratic short-cycling
  • Blower runs continuously or fails to start

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS336LEFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS336LEFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS336LEFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online