This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP/Heil/Tempstar RGS303HSFA0AAAA gas furnace. It manages the ignition sequence, blower and inducer timing, safety lockouts, and communication between the thermostat, igniter, gas valve, and limit switches. A failed control board can leave the furnace completely dead, stuck in lockout, or short-cycling. Boards typically fail from power surges, cracked solder joints, blown onboard fuses, or burned relay contacts. This kit ships with the matched OEM board so the furnace's diagnostic LED, timings, and safety logic behave exactly as designed.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24V
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar/Comfortmaker RGS303HSFA0AAAA gas furnace. Confirm OEM part number 1183618 and the board's connector layout against your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire harness and terminal position before disconnecting anything.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer connectors one at a time per your photos, and set any dip switches/jumpers to match the original.
  6. Test — Restore power, watch the diagnostic LED, and run a full heat cycle to confirm proper ignition and blower operation.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no diagnostic LED.
  • Repeated lockouts or fault codes that persist after replacing igniter/flame sensor.
  • Blower or inducer runs continuously or fails to start.
  • Visible burn marks, blown fuse, or corroded relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303HSFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303HSFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303HSFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.