The OEM Control Board Kit (part #1183618) is the integrated furnace control (IFC) that manages the complete heating sequence for your ICP Tempstar Heil RGS300HDFA0AAAA gas furnace. This board orchestrates ignition timing, gas valve operation, blower control, and flame sensing, while running continuous self-diagnostics and flashing fault codes through its onboard LED. When the control board fails, the furnace loses its 'brain' — even when every other component is healthy. Common failure symptoms include no response from the thermostat, the furnace failing to ignite, the inducer or blower running continuously, intermittent lockouts, or burned/corroded relay contacts on the board itself. Power surges, overheating, moisture intrusion, and aged relays are the usual culprits. This is a factory OEM kit, so it ships with the correct firmware and connector layout for a true plug-and-play replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fitment OEM Direct Replacement
Diagnostics LED fault-code indicator

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil RGS300HDFA0AAAA gas furnace. ICP-built equipment is sold under multiple brands — Comfortmaker, Arcoaire, KeepRite, and Day & Night — so this board fits many cross-branded units sharing the same chassis. Always verify the printed part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the service switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire harness and connector position before disconnecting.
  4. Remove — Unplug all low- and line-voltage connectors, release the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, then reconnect each harness exactly per your photos.
  6. Test — Restore power, call for heat, and confirm a full ignition cycle with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to thermostat calls
  • Blower or inducer motor runs nonstop or won't start
  • Repeated ignition lockouts or erratic LED fault codes
  • Visible burn marks, corrosion, or swollen relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HDFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HDFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HDFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.