Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS244HFFA0AAAA — Direct OEM Replacement Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS244HFFA0AAAA — Direct OEM Replacement Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board (kit 1183618) is the brain of the ICP Tempstar/Heil RGS244HFFA0AAAA gas furnace. It manages the ignition sequence, blower and inducer timing, safety lockouts, and 24V relay logic that ties the thermostat, gas valve, igniter, and limit switches together. When this board fails the furnace typically will not start, short-cycles, locks out after a few ignition attempts, or runs the blower continuously. The replacement ships as a complete kit with the board and mounting hardware so you can restore reliable heating without piecing parts together.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS244HFFA0AAAA
Fitment Direct OEM Replacement

Compatibility

Engineered specifically for the ICP Tempstar Heil RGS244HFFA0AAAA gas furnace. Because ICP, Tempstar, Heil, Comfortmaker, and Arcoaire share this platform, the 1183618 board is commonly used across closely related RGS-series furnaces. Always confirm your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every low-voltage and line-voltage wire connected to the old board before disconnecting anything.
  4. Remove — Label and unplug each connector, remove the mounting screws/standoffs, and lift out the failed control board.
  5. Install — Mount the new 1183618 board, then reconnect each harness exactly as shown in your photos.
  6. Test — Restore power and run a full heat cycle; confirm proper ignition, blower delay, and that no diagnostic fault LED is flashing.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly locks out after several attempts
  • Blower or inducer motor runs constantly or never starts
  • Diagnostic LED shows a hard fault or no light at all
  • Visible burn marks, corrosion, or scorched traces/relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HFFA0AAAA — Direct OEM Replacement Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HFFA0AAAA — Direct OEM Replacement Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HFFA0AAAA — Direct OEM Replacement Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online