This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS244HFAA0AAAA gas furnace. The control board is the brain of the furnace — it sequences ignition, monitors safety circuits, runs the inducer and blower motors, and communicates with the thermostat. When it fails, the furnace will not respond to heat calls, may short-cycle, throw repeating fault flash codes, or fail to ignite at all. This factory-supplied kit includes the correctly programmed board and mounting hardware to drop directly into your existing furnace.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS244HFAA0AAAA
Fitment OEM direct replacement

Compatibility

Engineered for the ICP-family RGS244HFAA0AAAA furnace sold under the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always confirm the part number printed on your existing board matches 1183618 before installation, as control board kits are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector on the old board before disconnecting anything.
  4. Remove — Unplug the molex harnesses and spade terminals, remove the mounting screws/standoffs, and lift out the failed board.
  5. Install — Mount the new board on the supplied standoffs and reconnect every harness exactly as photographed.
  6. Test — Restore power, run a full heat cycle, and confirm ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead and ignores thermostat heat calls.
  • Repeating or erratic LED fault/flash codes on the board.
  • Blower or inducer runs continuously or never starts.
  • Visible burn marks, scorched relays, or corroded traces on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HFAA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HFAA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HFAA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.