Overview

The 1183618 control board kit is the OEM integrated furnace control (IFC) for the ICP Tempstar Heil RGS244HEFA0AAAA gas furnace. This board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors flame and limit safeties, and times each heating and cooling call. When it fails, the furnace typically loses heat entirely, locks out on a flashing diagnostic LED, or short-cycles the blower. The kit ships with the board and the mounting hardware needed for a direct OEM replacement, operating on the standard 24V control circuit.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Control
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Gas Furnace
Fitment OEM Replacement

Compatibility

Designed as the factory replacement control board for the ICP Tempstar Heil RGS244HEFA0AAAA furnace and other models in the RGS family that originally shipped with the 1183618 board. Always match your existing board's part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the service switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment door to expose the control board.
  3. Document — Photograph every wire and connector location before disconnecting anything.
  4. Remove — Unplug all molex connectors and spade terminals, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new 1183618 board, then reconnect every harness exactly as photographed.
  6. Test — Restore power and run a full heat and cool cycle, watching the diagnostic LED for normal operation.

Signs You Need a Replacement

  • No ignition or no response on a call for heat
  • Blower or inducer runs continuously or fails to start
  • Flashing fault code or hard lockout on the control LED
  • Visible scorch marks, corrosion, or a blown trace on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HEFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HEFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HEFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.