Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS243SRFA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS243SRFA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board (kit part number 1183618) for the ICP / Tempstar / Heil RGS243SRFA0AAAA gas furnace. The control board manages the entire heating sequence — it controls ignition timing, sequences the inducer and blower motors, monitors flame sense and safety limits, and reports faults via diagnostic LEDs. A failed board commonly results in a furnace that will not ignite, short-cycles, blows cold air, or clears its symptoms only after a power reset.

Specifications

Spec Value
Part Number 1183618 (Kit Control Board)
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil)
Fits Model RGS243SRFA0AAAA
Application Gas Furnace Ignition Control
Fitment OEM Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP RGS243SRFA0AAAA gas furnace and closely related RGS-series models built on the same control platform. Always confirm your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace front service panel and locate the control board in the burner compartment.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug all low- and line-voltage connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, reconnect every connector exactly per your photo, and confirm the ground.
  6. Test — Restore power and run a full heat cycle; confirm ignition, blower, and a steady status LED.

Signs You Need a Replacement

  • Furnace will not ignite or start a heat cycle
  • Flashing diagnostic LED fault codes on the board
  • Blower or inducer runs erratically or not at all
  • Intermittent no-heat calls that clear after a power reset

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243SRFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243SRFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243SRFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online