Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS243SEAA0AAAA — OEM 1183618 Control Board Kit | Ships Today
ICP

ICP Furnace Control Board for RGS243SEAA0AAAA — OEM 1183618 Control Board Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS243SEAA0AAAA gas furnace. This board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety limits and flame sense, and communicates with the thermostat. When the board fails, the furnace may not respond to a heat call, may short-cycle, may run the blower continuously, or may flash a diagnostic fault code. This genuine OEM kit ships with the correct board to restore full furnace operation.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control Board
Brand ICP (Tempstar / Heil)
Fits Model RGS243SEAA0AAAA
Fit OEM Replacement

Compatibility

Built as a direct-fit replacement for the ICP Tempstar Heil RGS243SEAA0AAAA furnace and other ICP-family gas furnaces that specify OEM part 1183618. ICP, Tempstar, Heil, and Comfortmaker furnaces commonly share control boards across model lines. Verify your furnace calls for 1183618 before ordering to ensure correct fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting — this is critical for a correct reconnection.
  4. Remove — Unplug all harness connectors and low-voltage wires, remove the board mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, then reconnect every wire and connector exactly per your photos. Set any DIP switches/jumpers to match the original board.
  6. Test — Restore power and run a full heat cycle. Confirm proper ignition, inducer and blower staging, and a clear (no-fault) diagnostic LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive to a thermostat call for heat.
  • Blower runs constantly or fails to start on a heat cycle.
  • Persistent diagnostic fault codes or no LED activity on the board.
  • Intermittent operation, short-cycling, or scorched/burned spots on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243SEAA0AAAA — OEM 1183618 Control Board Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243SEAA0AAAA — OEM 1183618 Control Board Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243SEAA0AAAA — OEM 1183618 Control Board Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online