This OEM integrated furnace control board (kit 1183618) is the central controller for the ICP/Tempstar/Heil RGS243HTFA0AAAA gas furnace. It sequences ignition, controls blower on/off timing, monitors the flame-sense safety circuit, and watches the limit and pressure switches. A failed board typically causes no ignition, short-cycling, premature lockout, or blinking fault codes on the diagnostic LED. Heat-stressed relays, corroded connectors, and cracked solder joints are the usual culprits. As a genuine OEM kit, its relay ratings, connector pinouts, and control timing match the furnace precisely — avoiding the miswire and timing problems that plague universal boards.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Gas Furnace Ignition & Blower Control
Fit OEM Replacement

Compatibility

Engineered for the ICP/Tempstar/Heil RGS243HTFA0AAAA gas furnace and shared across several RGS-series furnaces of this generation. Confirm the printed part number 1183618 on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the molex harnesses, release the board standoffs/screws, and lift the old control board out.
  5. Install — Mount the new board on the standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, call for heat, and confirm a complete ignition and blower cycle with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or blower never energizes
  • Repeated safety lockouts or blinking diagnostic fault codes
  • Visible burn marks, melted relays, or corrosion on the board
  • Intermittent operation that worsens with heat or vibration

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243HTFA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243HTFA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243HTFA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online