Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS243HDEA0AAAA — Integrated Ignition Control Kit | Ships Today
ICP

ICP Furnace Control Board for RGS243HDEA0AAAA — Integrated Ignition Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM integrated furnace control board kit (OEM part #1183618) for the ICP / Tempstar / Heil RGS243HDEA0AAAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety limits and the flame signal, and coordinates the gas valve and igniter. When the board fails the furnace may not start at all, may lock out after a few ignition attempts, may short-cycle, or may run the blower continuously. A cracked solder joint, blown onboard fuse, or burned relay contact on the board is one of the most common causes of a no-heat call on these units. This kit ships as a complete OEM replacement so you restore factory ignition logic and safety timings exactly.

Specifications

Spec Value
OEM Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Ignition Control
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Gas Furnace
Fit OEM Direct Replacement

Compatibility

Designed as a direct OEM fit for the ICP Tempstar Heil RGS243HDEA0AAAA gas furnace. Because ICP builds under multiple brand labels, this same board is used across matching Tempstar, Heil, Comfortmaker, and other ICP-family furnaces sharing OEM #1183618. Always confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage at the board with a multimeter before touching any terminals.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug the molex connectors and individual leads, remove the mounting screws/standoffs, and lift out the failed board.
  5. Install — Mount the new board on the same standoffs and reconnect every wire and connector exactly per your photos.
  6. Test — Restore power, initiate a heat call, and confirm the full ignition sequence: inducer, igniter glow, gas valve, flame proof, and blower-on.

Signs You Need a Replacement

  • Furnace will not start or has no response to a heat call.
  • Repeated ignition lockout or blinking fault/diagnostic LED on the board.
  • Blower runs continuously or won't start even though the burners light.
  • Visible burn marks, swollen relays, or a blown fuse on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243HDEA0AAAA — Integrated Ignition Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243HDEA0AAAA — Integrated Ignition Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243HDEA0AAAA — Integrated Ignition Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online