This is the OEM integrated furnace control board for the ICP (Tempstar / Heil) RGS214HDHLBRETA gas furnace. The control board is the brain of the unit — it manages the ignition sequence, blower timing, safety lockouts, and the reheat circuit, while coordinating signals between the thermostat, igniter, gas valve, and indoor blower motor. This listing covers the OEM control board kit (part 1183618), the reheat circuit board (1186501), and the IFCB-to-IFM wiring harness (1186494) that ties the board to the indoor fan motor. When the board fails, the furnace typically will not start, short-cycles, or throws blinking fault codes at the diagnostic LED. Specs: 24V control logic, on-board diagnostics, integrated reheat circuit.

Specifications

Spec Value
Part Number 1183618 (Kit), 1186501 (Reheat), 1186494 (Harness)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Features Reheat circuit, on-board diagnostics, blower timing
Fits Model RGS214HDHLBRETA

Compatibility

Engineered for the ICP Tempstar/Heil RGS214HDHLBRETA furnace. ICP-built brands (Heil, Tempstar, Comfortmaker, Arcoaire) share many control platforms — verify your existing board part number against 1183618 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment door to expose the control board.
  3. Document — Photograph every wire and connector before disconnecting anything.
  4. Remove — Unplug all harness connectors, release the board mounting tabs/screws, and lift the old board out.
  5. Install — Mount the new board, reconnect each harness exactly per your photo, and seat the IFCB-to-IFM harness.
  6. Test — Restore power, run a heat cycle, and confirm the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • Furnace will not ignite or blower never starts
  • Continuous or coded fault flashes at the diagnostic LED
  • Short-cycling or erratic blower behavior
  • Visible scorching, corrosion, or blown traces on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS214HDHLBRETA — Integrated Reheat Board Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS214HDHLBRETA — Integrated Reheat Board Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS214HDHLBRETA — Integrated Reheat Board Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online