Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS213LRCA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS213LRCA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM Control Board Kit (part #1183618) is the integrated furnace control (IFC) module that manages ignition sequencing, blower and inducer timing, safety lockouts, and flame supervision on the ICP Tempstar Heil RGS213LRCA0AAAA gas furnace. When this board fails, the furnace typically will not ignite, the blower runs continuously or not at all, or a diagnostic LED flashes a fault code. A failed control board is one of the most common causes of intermittent no-heat calls. This is a complete factory kit, supplied with the correct relays, microprocessor, and connectors to match the original equipment exactly.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Fits Model RGS213LRCA0AAAA
Function Ignition, blower & inducer timing, flame sensing, safety lockout
Fitment OEM direct replacement

Compatibility

Engineered as the factory replacement for the ICP Tempstar Heil RGS213LRCA0AAAA gas furnace. The same board kit is used across closely related RGS-series ICP-family furnaces. Always confirm your existing board part number before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph all wire harness connections and terminal positions before disconnecting.
  4. Remove — Unplug each connector, release the board mounting standoffs/screws, and lift out the old control board.
  5. Install — Mount the new board, then reconnect every harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle; confirm ignition, flame proof, and blower handoff with no fault codes.

Signs You Need a Replacement

  • Furnace will not start or ignite, with no inducer or igniter activity
  • Diagnostic LED flashing a hard-lockout or control fault code
  • Blower runs constantly or fails to start after ignition
  • Intermittent operation, random shutdowns, or no response to thermostat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213LRCA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213LRCA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213LRCA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online