Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS213LFAA0AAAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS213LFAA0AAAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP / Heil / Tempstar RGS213LFAA0AAAA. The board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety limits and flame, and runs the onboard diagnostic LED. A failed board typically presents as a dead furnace, a furnace stuck on continuous blower, no inducer start, or a flashing fault code that points back to the control. Supplied as a complete kit for a clean, direct replacement.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Control Voltage 24V
Brand ICP / Heil / Tempstar
Fits Model RGS213LFAA0AAAA
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement control board kit for the ICP/Heil/Tempstar RGS213LFAA0AAAA furnace and Comfortmaker-family units originally equipped with OEM part 1183618. Match the board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire harness and plug position before disconnecting anything.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board and reconnect every harness exactly as photographed; confirm dip-switch and jumper settings match.
  6. Test — Restore power, run a full heat cycle, and verify the diagnostic LED shows a normal status code.

Signs You Need a Replacement

  • Furnace is completely unresponsive on a heat call.
  • Inducer or blower fails to start, or blower runs continuously.
  • Diagnostic LED is dark or flashing a control/board fault code.
  • Visible scorching, burnt relays, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213LFAA0AAAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213LFAA0AAAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213LFAA0AAAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online