Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS210LEAA0AAAA — OEM Integrated Furnace Control Kit | Ships Today
ICP

ICP Furnace Control Board for RGS210LEAA0AAAA — OEM Integrated Furnace Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board kit (part number 1183618) for the ICP Tempstar Heil RGS210LEAA0AAAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, blower and inducer timing, safety lockouts, and communication between the thermostat, gas valve, and igniter. When this board fails, the furnace may not respond to thermostat calls, lock out repeatedly, run the blower continuously, or fail to ignite. Replacing it with a factory part ensures correct timing and full compatibility with the RGS210 platform's safety circuits.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Fits Model RGS210LEAA0AAAA
Application Gas Furnace
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct replacement for the ICP Tempstar Heil RGS210LEAA0AAAA gas furnace. This kit ships with the mounting hardware and instructions needed for a factory-correct install. Confirm your unit's model and serial label before ordering to ensure exact fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph all wire harness connections and terminal positions before disconnecting.
  4. Remove — Unplug the harnesses, release the board standoffs, and lift out the failed control board.
  5. Install — Mount the new board on the standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm ignition, blower, and inducer operate correctly.

Signs You Need a Replacement

  • Furnace does not respond to thermostat heat calls.
  • Repeated ignition lockouts or error/flash codes on the board LED.
  • Blower or inducer motor runs continuously or won't start.
  • Visible burn marks, corrosion, or scorched relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210LEAA0AAAA — OEM Integrated Furnace Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210LEAA0AAAA — OEM Integrated Furnace Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210LEAA0AAAA — OEM Integrated Furnace Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online