This is the genuine OEM furnace control board kit (part number 1183618) for the ICP Tempstar Heil RGS121HFCB0AAA gas furnace. The integrated furnace control board is the brain of your heating system — it manages the ignition sequence, monitors safety limits and flame sensing, controls the inducer and blower motors, and coordinates the gas valve timing. When this board fails, the furnace may fail to ignite, short-cycle, lock out, or stop responding to thermostat calls entirely. Common failure symptoms include a furnace that hums but won't start, an LED fault code on the board, blown low-voltage fuses, or intermittent no-heat conditions that come and go with temperature. This kit ships complete and ready to install as a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS121HFCB0AAA
Fitment OEM Direct Replacement
Application Gas Furnace

Compatibility

This control board kit is engineered specifically for the ICP Tempstar Heil RGS121HFCB0AAA furnace and related ICP-family equipment using OEM part 1183618. Always verify the part number printed on your existing board before ordering. ICP, Tempstar, Heil, and Comfortmaker share many components across these gas furnace platforms.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access – Remove the furnace blower/control compartment service panel.
  3. Document – Photograph every wire and connector position on the board before disconnecting anything.
  4. Remove – Unplug each harness, release the board mounting standoffs or screws, and lift the old board out.
  5. Install – Seat the new board on the standoffs and reconnect every harness exactly per your photo.
  6. Test – Restore power, call for heat, and verify the full ignition sequence and blower operation.

Signs You Need a Replacement

  • Furnace will not respond to the thermostat or fails to ignite
  • Visible burn marks, corrosion, or a blinking fault LED on the board
  • Repeated blown 3-amp low-voltage fuses
  • Intermittent no-heat or short-cycling that resists other fixes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121HFCB0AAA – OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121HFCB0AAA – OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121HFCB0AAA – OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.