Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS120LRCA0AAA — 24V Integrated Control Kit | Ships Today
ICP

ICP Furnace Control Board for RGS120LRCA0AAA — 24V Integrated Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP integrated furnace control board (PN 1183618, KIT CONTROL BOARD) is the brain of your RGS120LRCA0AAA gas furnace. It manages the ignition sequence, blower timing, gas valve operation, safety lockouts, and diagnostic fault codes. Operating on a 24V control circuit, it coordinates the thermostat call, inducer, igniter, and flame sensing to deliver safe, reliable heat. A failed control board is one of the most common causes of a furnace that won't ignite, short-cycles, runs the blower continuously, or flashes diagnostic error codes. Replacing it with a genuine OEM kit restores correct timing and full diagnostic capability.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24V
Fits Model RGS120LRCA0AAA
Fitment OEM Direct Replacement

Compatibility

Designed as a direct OEM replacement for the ICP RGS120LRCA0AAA gas furnace and shared platform models across the Tempstar, Heil, and Comfortmaker families that originally used part 1183618. Always verify your existing board's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting.
  4. Remove — Label and unplug each harness, release the board mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, then reconnect every harness exactly per your photos.
  6. Test — Restore power, initiate a heat call, and confirm a full ignition sequence with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or has no response to a thermostat call
  • Blower runs continuously or fails to start
  • Repeated short-cycling or random lockouts
  • Diagnostic LED flashing error/fault codes or no LED at all

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LRCA0AAA — 24V Integrated Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LRCA0AAA — 24V Integrated Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LRCA0AAA — 24V Integrated Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online