The ICP control board kit (OEM 1183618) is the integrated furnace control (IFC) that manages the entire heating sequence on the Tempstar/Heil RGS102SRCB0AAA gas furnace. It governs the ignition sequence, monitors the flame sensor and pressure switches, sequences the inducer and blower motors, and protects the system through safety lockouts. When this 24V board fails, the furnace typically will not start, locks out after a few ignition attempts, runs the blower continuously, or throws diagnostic flash codes on the LED. This is a complete OEM replacement kit supplied with the correct mounting hardware and wiring harness for a true plug-and-play swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fitment OEM Direct Replacement
Application Gas Furnace

Compatibility

Engineered for the ICP / Tempstar / Heil / Comfortmaker RGS102SRCB0AAA gas furnace and related RGS102 series chassis that specify OEM kit 1183618. Always confirm the board part number printed on your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the existing board before disconnecting anything.
  4. Remove — Unplug the molex harnesses and spade terminals, remove the mounting screws, and lift out the old control board.
  5. Install — Mount the new OEM board, then reconnect every harness and terminal exactly as photographed.
  6. Test — Restore power and confirm a full heat cycle: inducer, ignition, flame proof, and blower.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly locks out
  • Blower runs constantly or never engages
  • Diagnostic LED shows a fault or no light at all
  • Visible scorching, burnt traces, or failed relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102SRCB0AAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102SRCB0AAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102SRCB0AAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online