Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS102LTBA0AAA — OEM Ignition Board Kit | Ships Today
ICP

ICP Furnace Control Board for RGS102LTBA0AAA — OEM Ignition Board Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP / Heil / Tempstar RGS102LTBA0AAA gas furnace. It sequences the ignition cycle, monitors flame and safety switches, controls the inducer and blower motors, and manages timing for heating and cooling calls. When this board fails, the furnace may fail to ignite, lock out intermittently, run the blower continuously, or stop responding to the thermostat entirely. This kit ships with the correct board and mounting hardware for a direct OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Function Ignition, blower, inducer, and safety timing
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP/Heil/Tempstar RGS102LTBA0AAA gas furnace and related models on the same control platform. Match your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the service switch and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment door.
  3. Document — Photograph every wire connection and the existing dip-switch / jumper settings before disconnecting.
  4. Remove — Label and unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer dip-switch / jumper settings to match, and reconnect every wire per your photos.
  6. Test — Restore power, call for heat and cool, and confirm correct ignition and blower operation.

Signs You Need a Replacement

  • No response from the furnace on a heat call
  • Repeated ignition lockouts with a healthy igniter and flame sensor
  • Blower runs constantly or not at all
  • Burnt spots, corrosion, or a tripped onboard fuse on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LTBA0AAA — OEM Ignition Board Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LTBA0AAA — OEM Ignition Board Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LTBA0AAA — OEM Ignition Board Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.