Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS102LFAB0AAA — OEM Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board for RGS102LFAB0AAA — OEM Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board (part #1183618, KIT CONTROL BOARD) is the brain of your ICP RGS102LFAB0AAA gas furnace. It manages the ignition sequence, monitors the flame sensor and pressure switches, sequences the inducer and blower motors, and controls gas valve timing. A failed control board is one of the most common causes of a furnace that won't ignite, short-cycles, or runs the blower continuously. The board operates on 24V control logic and includes onboard diagnostic LED fault codes to speed troubleshooting.

Specifications

Spec Value
Part Number 1183618
Type Integrated Ignition Control Board (Kit)
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24V
Function Ignition, blower & inducer sequencing, flame sense, safety monitoring
Diagnostics Onboard LED fault codes
Fit OEM Replacement

Compatibility

Designed as a direct OEM replacement for the ICP RGS102LFAB0AAA gas furnace and related Tempstar, Heil, and Comfortmaker models that originally shipped with control board kit 1183618. Always confirm your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower compartment service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Unplug all molex connectors and spade terminals, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect every harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle; confirm ignition, blower, and the diagnostic LED show normal operation.

Signs You Need a Replacement

  • Furnace fails to ignite or you hear no inducer/igniter sequence on a call for heat
  • Blower runs constantly or never starts
  • Furnace short-cycles or locks out on repeated fault codes
  • Diagnostic LED is dark, flashing an error, or visibly burned/corroded board traces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LFAB0AAA — OEM Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LFAB0AAA — OEM Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LFAB0AAA — OEM Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online