This OEM control board kit (part #1183618) is the brain of the ICP/Heil/Tempstar RGS102HFAB0AAA gas furnace. It sequences the entire heat cycle — energizing the inducer, proving pressure, firing the hot surface igniter, opening the gas valve, and timing the blower on/off delays. It also monitors flame, limit, and rollout safeties and reports fault codes via its diagnostic LED. A failed board produces erratic, hard-to-diagnose behavior: blowers that won't shut off, ignition sequences that never start, or a completely dead furnace. The kit ships with the OEM board and mounting hardware for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board (Kit)
Brand ICP / Heil / Tempstar
Line Voltage 120V
Control Voltage 24V
Fitment OEM

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RGS102HFAB0AAA furnace and shared-platform ICP brands (Comfortmaker, Arcoaire, Day & Night). Verify the printed part number on your existing board before ordering, as ICP furnace boards vary by series.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the furnace control/blower access panel.
  3. Document – Photograph every wire and connector on the board before removing anything; label harnesses if needed.
  4. Remove – Disconnect all plugs and spade terminals, remove the mounting screws, and lift out the old board.
  5. Install – Mount the new board, then reconnect each harness exactly per your photos. Confirm the line-voltage and 24V connections are correct.
  6. Test – Restore power, run a full heat cycle, and watch the diagnostic LED for a normal (no-fault) code.

Signs You Need a Replacement

  • Furnace is completely dead with no LED activity
  • Blower runs constantly or won't start on a heat call
  • Ignition sequence never begins despite good igniter and gas valve
  • Diagnostic LED flashes a hard-fault code that persists after resetting safeties

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HFAB0AAA – OEM Kit 1183618 120V | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HFAB0AAA – OEM Kit 1183618 120V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HFAB0AAA – OEM Kit 1183618 120V | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.