Overview

This genuine OEM control board kit (part #1183618) is the integrated furnace control (IFC) that runs every safety and sequencing function in your ICP, Heil, or Tempstar RGS091SECB0AAA gas furnace. It manages the inducer, hot surface igniter, gas valve timing, blower fan-on/fan-off delays, flame sensing, and the diagnostic LED fault codes. When the board fails, symptoms range from a completely dead furnace to erratic blower operation, short cycling, or repeated ignition lockouts. Because the IFC ties every component together, a failing board is often misdiagnosed as an igniter, gas valve, or blower problem — this kit restores the furnace to factory control logic.

Specifications

Spec Value
Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control (IFC)
Brand ICP / Heil / Tempstar
Control Voltage 24V
Line Voltage 120V
Diagnostics On-board LED fault codes
Fitment OEM exact replacement kit

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS091SECB0AAA gas furnace. This control kit is used across numerous RGS-series ICP-family furnaces — verify your model and existing board part number against 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board and reconnect each harness exactly per your photos, matching connector to terminal.
  6. Test — Restore gas and power, run a full heat cycle, and confirm the diagnostic LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Blower runs continuously or won't start at all
  • Repeated ignition lockouts with no component fault found
  • Diagnostic LED dark, frozen, or flashing a hard-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091SECB0AAA — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091SECB0AAA — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091SECB0AAA — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online