Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS091LTCB0AAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS091LTCB0AAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP RGS091LTCB0AAA gas furnace. The board is the brain of the system: it sequences the inducer, hot surface igniter, gas valve, and blower; monitors safety inputs from the pressure switch, limit, and flame sensor; and manages timing, fault diagnostics, and the LED error codes. When the board fails, the furnace may be completely dead, stuck on a continuous blower, locked out with a flashing fault code, or short-cycling. Common failure causes include power surges, lightning, overheating from a restricted blower, corroded relays, and cracked solder joints. Replacing the board with the correct OEM kit restores full, code-correct furnace operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar)
Fits Model RGS091LTCB0AAA
Function Ignition, blower, and safety circuit control
Fitment OEM direct replacement

Compatibility

Designed for the ICP / Heil / Tempstar RGS091LTCB0AAA gas furnace and shared-platform models using this integrated control. Match the part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off gas. Verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to reach the control board.
  3. Document — Photograph every wire and connector position before disconnecting — this is critical for a board swap.
  4. Remove — Unplug the harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer any jumpers/settings, and reconnect each plug per your photos.
  6. Test — Restore power and gas, then run a full heat cycle and confirm no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive (no ignition sequence)
  • Flashing fault/error codes or board diagnostic lockout
  • Blower runs constantly or won't start
  • Short-cycling or erratic, intermittent operation

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091LTCB0AAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091LTCB0AAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091LTCB0AAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online