This OEM control board kit (part #1183618) is the integrated furnace control (IFC) — the brain of the ICP/Heil/Tempstar RGS091LFCA0AAA gas furnace. It sequences the entire heat cycle: powering the inducer, proving pressure, energizing the hot surface igniter, opening the gas valve, monitoring flame, and timing the blower on/off delays. It also enforces safety lockouts from the limit and rollout switches. A failed board causes intermittent no-heat, the furnace ignoring the thermostat, blower running constantly, or rapid LED fault codes. Because it controls every safety interlock, a marginal board should always be replaced with the correct OEM part.

Specifications

Spec Value
Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control (IFC)
Brand ICP / Heil / Tempstar
Function Ignition, blower, and safety sequencing
Fits Model RGS091LFCA0AAA

Compatibility

Designed for the ICP/Heil/Tempstar/Comfortmaker RGS091LFCA0AAA furnace and related RGS-series 90%+ AFUE units. Confirm the board part number printed on your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every harness connection and note wire colors/terminal positions.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and reconnect every harness exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat call for heat
  • Blower runs continuously or never starts
  • Erratic short cycling or random no-heat events
  • Diagnostic LED flashing a hard-lockout or board fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091LFCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091LFCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091LFCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.