Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS091HSCB0AAA — OEM Kit 1183618 | Ships Today
ICP

ICP Furnace Control Board for RGS091HSCB0AAA — OEM Kit 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The integrated furnace control board is the electronic brain of your ICP / Heil / Tempstar RGS091HSCB0AAA gas furnace. This OEM kit (part number 1183618) manages the complete ignition and safety sequence — it powers the inducer motor, energizes the hot surface igniter, opens the gas valve, monitors flame via the sensor, and controls blower timing for both heating and cooling calls. When this board fails, the furnace simply will not respond correctly to the thermostat. Common failure symptoms include no ignition at all, a furnace that short-cycles, blower motor that runs constantly or never starts, a flashing diagnostic LED error code, or burnt/cracked relays visible on the board itself. Power surges, moisture, and overheated relays are the usual culprits.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Line Voltage 115 VAC
Control Voltage 24 VAC
Ignition Type Hot Surface Ignition
Fit OEM Direct Replacement

Compatibility

This control board kit is the factory-specified replacement for the ICP / Heil / Tempstar RGS091HSCB0AAA gas furnace. It is also used across many related RGS091 and RGS-series single-stage furnace platforms. Always confirm the printed part number on your existing board matches 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace front service panel and locate the control board in the blower compartment.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug all low- and line-voltage harnesses, release the mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new board on the standoffs and reconnect every harness exactly per your photos.
  6. Test — Restore power, run a heat call, and confirm the full ignition sequence and blower operation. Check the diagnostic LED for normal status.

Signs You Need a Replacement

  • Furnace does not ignite or respond to the thermostat
  • Blower runs continuously or fails to start
  • Diagnostic LED flashing a hard fault or staying off
  • Visible burn marks, melted relays, or scorching on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS091HSCB0AAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS091HSCB0AAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS091HSCB0AAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.